• Vibration isolation in all directions.
  • Noise attenuation.
  • Easy installation because of one-piece design.
  • Low-cost installation.
  • Long service life.
  • Consistent performance because of permanently bonded design.
  • Shock protection in all directions provided by cushioned snubbing, no metal-to-metal bottoming.
  • Standard sizes available from stock.
  • Space-saving size.
  • Captive installation after overload failure when recommended bolt, washer and nut are used.
  • Accommodate English and Metric bolts.
Unit of Measure

Specifications

Maximum Axial Static Load Rating at Deflection

N/A 2224 N at 2.3 mm 500 lbs at 0.09 in

Dimension A (± 0.015)

N/A 59.7 mm

Dimension B

N/A 0.657 in16.5 mm

Dimension C (± 0.015)

N/A 1.50 in38.1 mm

Dimension D (± 0.02)

N/A 2.11 in53.6 mm

Dimension E (± 0.015)

N/A 1.50 in38.1 mm

Dimension F (± 0.02)

N/A 0.69 in17.5 mm

Metal Parts

N/A Low Carbon Steel

Size Imperial (Recommended Bolt Information)

N/A 5/8

Size Metric (Recommended Bolt Information)

N/A M16

Grade or Class SAE J429 (Recommended Bolt Information)

N/A 2

Grade or Class SAE J1199 (Recommended Bolt Information)

N/A 5.8
Nominal Dynamic - Static Spring Rate Ratio1 N/A 1.15

Tolerances for Dimensions

N/A .xx = ± 0.03 in. (± 0.762 mm)
.xxx = ± 0.015 in. (± 0.381 mm)

Washer

N/A , Head Washer
, Tail Washer

Installation Dimensions

Dimension H

N/A 0.62 in15.7 mm

Dimension I

N/A 2.75 in69.9 mm

Dimension K

N/A 2.50 in63.5 mm

Dimension SD (± 0.03)

N/A 1.38 in35.1 mm

Dimension R (± 0.015)

N/A 0.06 in1.5 mm

Dimension T (± 0.03)

N/A 0.62 in15.7 mm

General Description

N/A Center Bonded Mounts provide flexible suspension systems for mobile, transport-mounted or portable equipment. Typical applications include engines, cabs, fuel tanks, pumps, air conditioning units, compressors and industrial machinery.

Application Engineering Assistance

N/A Frequently, vibration isolation problems require a system engineering analysis. Lord has the computer capability, as well as specialized programs, for analyzing engine/ transmission combinations. The output from this analysis is a mounting proposal which optimizes performance over the complete range of operating speeds. This service is available to you upon request.

Note

N/A Mounts and washers supplied by Lord.
Washers must be ordered separately.

  • 1 This figures can be used to calculate dynamic spring rate or natural frequency based on static values.

    (K DYN = KST x DYN/STATIC Ratio)