ASTRO-TEX CO., INC.
2512 Summit Ave, Suite 311
Plano, TX 75074
Tel: 972.424.8707 • Fax: 972.442.9791
Email: sales@astrotex.com
Website: www.AstroTex.com
All Categories > Lord Vibration Mounts > Bushings > Center Bonded Bushings > Item # J-6145  


Item # J-6145, Center Bonded Bushings without Outer Member


  • Easy to install.
  • Uncomplicated design provides initial economy.
  • High-strength bonding assures extended service life.
  • Minimal maintenance due to specially compounded elastomer






Specifications  · General Description  · Note

Specifications

Maximum Radial Static Load Rating

8200 lbs
36475
N

Spring Rate Radial (K rad)

312000 lbs/in
54631
N/mm

Torsional

796 lbs-in/deg
139.4
N-mm/deg

Recommended Socket Diameter (± 0.015 (±0.38 mm))

4.00 in
101.60
mm

Recommended Socket Length

4.00 in
101.60
mm

Dimension A

2.008 in
51.0
mm

Dimension B

4.19 in
106.4
mm

Dimension C

6.00 in
152.4
mm

Dimension D

3.25 in
82.6
mm


General Description
Center Bonded Bushings are designed to be loaded radially and utilize a soft torsional spring rate to provide freedom in rotation. High radial restraint maintains the alignment between joined parts. They are not intended for use where extreme rotational motion will occur. Typical applications include heavy duty highway equipment, drilling equipment, harvesters, combines and industrial machinery.

Square Center Bonded Bushings accommodate angular movement and isolate vibratory disturbances in heavy equipment. These bushings combine a torsional spring with an elastomeric pivot and isolator. They provide positive torsional positioning and pivot action under the most demanding operating conditions. Typical applications include wheel suspensions, vibratory feeders, mobile power equipment and vibratory cable layers.

Easy to install, the uncomplicated designs of the Center Bonded and Square Bonded Bushings provide initial economy, while the rugged elastomers and high strength bonding assure extended service life.



Note
First determine the amount of static loading at the installation point. Then determine the conditions under which the joint will operate. The following should be used as a guide to part selection for Type "A" and Type "B" service.
TYPE A: Extreme conditions (reversing dynamic load or distortion at high frequency - over 600 cpm) use 1/3 the Radial Static Load Rating.
TYPE B: Average conditions (constant radial load, intermittent shock) use the Radial Static Load Rating.